PoolCalc.

Pool heater size calculator

The BTU it takes to raise your pool by a given number of degrees, how long a heater of that size takes, and the heat loss the brochure leaves out.

Default result

11.4 hours to raise 14°F

20,000 gal · 250,000 BTU/hr input at 82% efficiency

Heat needed 2,335,200 BTU 20,000 gal × 8.34 lb × 14°F
Heater output 205,000 BTU/hr 250,000 BTU input × 82%
Time to heat 11.4 hours With no heat loss and a covered pool
For a 24-hour rise 97,300 BTU/hr Minimum output to hit the target in a day
Smallest standard size 150,000 BTU/hr input Closest common catalog size at this efficiency
  • BTU = gallons × 8.34 lb/gal × temperature rise. One BTU raises one pound of water by 1°F.
  • The heater delivers 205,000 BTU/hr, so 2,335,200 BTU takes 11.4 hours — before any heat loss.
  • Sizing for a 24-hour rise is a common target: fast enough to recover from a cold night without running continuously.

Before you dose

  • Real pools lose heat while they heat: an uncovered pool loses most of it overnight, and wind and cool air can double the time.
  • A solar cover is not optional for a heated pool. It cuts evaporation, which is where most of the heat goes.
  • A gas heater needs gas supply, venting and clearance to combustibles. Sizing is a job for a licensed installer, not a catalogue.
  • A heat pump moves heat rather than making it, so its efficiency is quoted as COP and it heats slowly in cold air. This calculator models a gas heater.

Other ways to do it

  • 14.8 h — A realistic allowance of 30% for an uncovered pool in cool air.
  • 97,300 BTU/hr — The minimum for a one-day rise; a larger heater gets there faster but cycles more.

The default pool: 20,000 gallons, 68 → 82°F

Raising 20,000 gallons by 14°F takes 2,335,200 BTU. A 250,000 BTU/hr heater at 82% efficiency delivers 205,000 BTU/hr, so the arithmetic says 11.4 hours. To do it in a single day you would need about 97,300 BTU/hr of output, which is why the smallest standard size the calculator suggests is 150,000 BTU/hr input.

That 11.4 hours is a floor, not a forecast. It assumes no heat loss at all: no wind, no evaporation, a cover on the pool and water at the same temperature throughout. A real uncovered pool in cool air takes considerably longer, and the calculator says so rather than pretending otherwise.

The formula

BTU = gallons × 8.34 lb/gal × temperature rise

One BTU raises one pound of water by 1°F. A US gallon weighs 8.34 lb, so the total heat is just the mass times the rise. The heater's output is its input rating times its efficiency; the time is the total divided by the output.

Heater inputOutput at 82%Time for 14°F in 20,000 gal
100,000 BTU/hr82,000 BTU/hr28.5 h
150,000 BTU/hr123,000 BTU/hr19.0 h
200,000 BTU/hr164,000 BTU/hr14.2 h
250,000 BTU/hr205,000 BTU/hr11.4 h
300,000 BTU/hr246,000 BTU/hr9.5 h
400,000 BTU/hr328,000 BTU/hr7.1 h

Why 82% is the default efficiency

The federal efficiency standard for gas-fired pool heaters is 82%, and the most efficient models reach about 95%. Using the minimum makes the time estimate conservative: a condensing heater will beat it, an older atmospheric heater will not.

Efficiency here is thermal efficiency — how much of the gas energy reaches the water. A heat pump is different: it is quoted as a coefficient of performance, often 4 to 6, because it moves heat rather than creating it. This calculator models a gas heater, which is why it asks for a BTU input and an efficiency percentage.

Sizing for recovery, not for the first swim

A pool heater is usually sized by how fast it can recover from a cold night, not by how fast it can heat a cold pool from scratch. Two rules of thumb are worth knowing:

If the pool is used every weekend, size for a two-day recovery and spend the difference on a cover. If it is used for a few weeks a year, a larger heater can make sense because you are heating from cold each time.

Where the heat actually goes

Evaporation is the largest loss for most pools, followed by radiation and convection from the surface, then plumbing and equipment. That is why a cover is the highest-leverage item in the whole system: ENERGY STAR reports that covers reduce heating needs by 50% to 70% and chemical use by 35% to 60%.

Wind is the other big variable. A pool on an exposed ridge loses far more heat than the same pool in a sheltered yard, and no heater size fixes a site that is open to a cold breeze. A windbreak, even a hedge, changes the number more than another 100,000 BTU.

What this calculator cannot tell you

The volume calculator gives you the gallons this page needs, and the pump runtime page covers the flow a heater requires.

Frequently asked

What size heater for a 20,000 gallon pool?

To raise 20,000 gallons by 14°F in a day takes about 97,000 BTU/hr of output. At 82% efficiency that is a 120,000 BTU/hr input, so the smallest standard size is 150,000 BTU/hr; 250,000 is the common choice for faster recovery.

How long does it take to heat a pool?

A 250,000 BTU/hr gas heater at 82% takes about 11.4 hours to raise 20,000 gallons by 14°F with no heat loss. Real pools lose heat overnight, so plan on 30% longer unless the pool is covered.

Is a bigger heater always better?

No. A larger heater heats faster but cycles more and needs a bigger gas supply and venting. Size for the recovery time you actually want, and put a cover on the pool before buying the next size up.

Heat pump or gas heater?

A gas heater heats fast and works in cold air, which suits a pool used occasionally. A heat pump moves heat instead of making it and is far more efficient in warm air, but it heats slowly and loses capacity as the air cools.

Does a pool cover really matter?

Yes. Covers cut heating needs by 50% to 70% according to ENERGY STAR, mostly by stopping evaporation. An uncovered pool can lose most of a day’s heat overnight.

Where these numbers come from

Figures that come from our own arithmetic rather than a published guide are marked house rule on the method page. No price is shown anywhere on this site.

Related: pump run time · pool volume · filter size · method and sources