PoolCalc.

Pool filter size calculator

The square footage a filter needs for the flow your pool runs at, in cartridge, sand or DE, and the nearest size that actually exists in a catalogue.

Default result

175 sq ft cartridge filter

41.7 gpm design flow · 20,000 gal in 8 hours

Design flow 41.7 gpm 20,000 gal ÷ 8 h ÷ 60
Filter rate used 0.25 gpm per sq ft Cartridge pleat rate
Minimum filter area 166.7 sq ft Flow ÷ rate
Nearest standard size 175 sq ft Cartridge filter
Rated flow at that size 43.8 gpm Must be at or above your design flow
  • Filter area = design flow ÷ the media’s design rate. The rate is a design convention, not a law: it keeps the water slow enough for the media to catch particles.
  • Design flow = volume ÷ run time ÷ 60, so a shorter run time needs more filter area.

Before you dose

  • A filter is sized on flow, not on how clean it looks. Oversizing is harmless and means less frequent cleaning; undersizing means the pump outruns the media.
  • Sand filters are backwashed, cartridges are hosed, DE grids are backwashed and recharged. The area above is the same number in each case, but the maintenance is not.
  • Check the pressure gauge after a clean. A rise of 8 to 10 psi is the usual cue to clean, whatever the calendar says.

Other ways to do it

  • 33.3 gpm — A 10-hour run instead of your figure: lower flow, smaller filter, longer cleaning interval.
  • One size up — Longer gaps between cleanings and a lower pressure rise; rarely a mistake.

The default pool: 20,000 gallons in 8 hours

20,000 gallons in 8 hours is 2,500 gallons per hour, or about 41.7 gallons per minute. At a conservative cartridge rate of 0.25 gpm per square foot, that needs 167 sq ft of pleated media, so the calculator points at the nearest standard size: 175 sq ft.

The same flow through sand at 15 gpm per square foot needs only 2.8 sq ft, which is a 24-inch tank. Through DE at 2 gpm per square foot it needs about 21 sq ft. The numbers look wildly different because the media are different: sand relies on a deep bed, DE on a thin cake of fossilised diatoms, and cartridge on a large pleated surface.

The formula

design flow = gallons ÷ hours ÷ 60

filter area = design flow ÷ media rate

The design flow is the average while the pump runs. The media rate is a design convention: it keeps the water slow enough for the media to catch particles instead of pushing them through. There is no single national standard for residential face velocity, so the calculator uses conservative values inside the ranges manufacturers publish, and labels them as house rules on the method page.

MediaRate usedTypical filtrationCleaning
Cartridge0.25 gpm/sq ft10 – 20 micronsHose the pleats; no backwash water
Sand15 gpm/sq ft20 – 40 micronsBackwash to waste
DE2 gpm/sq ft2 – 5 micronsBackwash and recharge with DE

The filtration figures are typical ratings quoted for each media, not a guarantee. A dirty cartridge filters finer and flows less; a channeled sand bed filters worse than its rating.

Why flow, not volume, sizes a filter

A filter does not care how much water is in the pool. It cares how fast water passes through the media. That is why the same 20,000 gallon pool needs a bigger filter when the pump runs six hours than when it runs twelve: the shorter run time means a higher flow, and the higher flow needs more area.

This is also why a filter can be "the right size for the pool" and still be wrong for the pump. A 2 hp pump on a 150 sq ft cartridge may move 70 gpm, which is 0.47 gpm per square foot — nearly double the conservative rate. The filter will work, but it will run at high pressure, need cleaning often, and let more fines through.

Choosing between the three media

Whichever you choose, the sizing arithmetic is the same. Buy one size up if the price difference is small: more media means a longer interval between cleanings and a lower pressure rise, and neither is a bad thing.

When the pressure gauge matters more than the size

A filter is clean at one pressure and dirty at another. The usual rule is to clean when the gauge reads 8 to 10 psi above the clean pressure. If the pressure is high right after a clean, the filter is undersized, the pump is too large, or the valve is partly closed. If the pressure never rises, water is bypassing the media.

Do not size a filter from horsepower. Two pumps of the same horsepower can move very different flows on different plumbing. Use the flow the pool actually needs, which comes from volume and run time.

What this calculator cannot tell you

Use the pump runtime page to get the run time this calculation assumes, and the volume page for the gallons. The runtime guide covers what happens when the filter and the schedule disagree.

Frequently asked

What size cartridge filter for a 20,000 gallon pool?

Running 8 hours a day, 20,000 gallons needs about 42 gpm. At a conservative 0.25 gpm per square foot of cartridge, that is 167 sq ft, so a 175 sq ft cartridge is the nearest standard size.

Is a bigger filter better?

Usually yes. A larger filter has more media, so it holds more dirt before the pressure rises and it can run at a lower flow. It costs more up front but needs cleaning less often.

Sand, cartridge or DE?

Sand is simple and backwashes to waste, and filters to roughly 20 to 40 microns. Cartridge filters to about 10 to 20 microns and uses no backwash water. DE filters finest, around 2 to 5 microns, but the media is messy to handle.

How often should I clean the filter?

When the pressure gauge reads 8 to 10 psi above the clean pressure, not on a calendar. A sand filter is backwashed, a cartridge is hosed, and a DE filter is backwashed and recharged.

Can my filter be too small for my pump?

Yes. If the pump moves more water than the filter is rated for, the media cannot catch particles and the pressure runs high. Match the filter to the design flow, not to the pump’s maximum.

Where these numbers come from

Figures that come from our own arithmetic rather than a published guide are marked house rule on the method page. No price is shown anywhere on this site.

Related: pump run time · pool volume · runtime guide · method and sources