Method and sources
A pool calculator is only useful if you can see the arithmetic. These are all 21 rules, 11 of them tied to a published source and 10 of them our own conservative choice, with the reason for each.
How a rule is labelled
Every number in every calculator comes from one of two places. A rule tied to a published source carries the publisher, the page and the date we read it. A house rule is our own arithmetic, used where no one publishes a figure — a shape multiplier, a design flow, a target inside a manufacturer's band — and it says why it exists.
There is no third category and no unlabelled number. If a figure appears on a calculator page and it is not in this table, it is either a unit conversion (a definition, not a recommendation) or an input you typed.
Where a source gives a range, the calculator uses the midpoint for its headline and shows the range beside it. That is why the chlorine page says "target 6 ppm" and also says "the band is 5 to 7". The midpoint is a choice; the band is the source.
Rendering: the default answer is in the HTML
Each calculator page is built with a default pool and its arithmetic is run at build time. The result — number, rows and warnings — is written into the static HTML. A reader with JavaScript switched off still sees the default answer; a reader who changes a field gets the same resolver running in the browser. The build fails if a default scenario refuses to calculate, so a page cannot ship with an empty result box.
Pool volume
| Rule | Formula | Basis |
|---|---|---|
| Rectangular volume 7.48 gallons per cubic foot is the US liquid gallon (231 in³) restated; NIST SP 811 gives 1 gal = 3.785 412 L. | L × W × avg depth × 7.48 | National Institute of Standards and Technology |
| Round volume Pentair publishes the same shape-by-shape method for round pools. | π × (D ÷ 2)² × avg depth × 7.48 | Pentair |
| Oval volume An oval is treated as an ellipse with the stated overall length and width. | π × L × W ÷ 4 × avg depth × 7.48 | Pentair |
| Kidney volume No published formula covers a kidney pool. 0.45 is a conservative multiplier between the 0.5 of an ellipse and the 0.4 of a very waisted shape. | 0.45 × L × W × avg depth × 7.48 | House rule |
| Average depth PoolMath uses the same straight-line average for a sloping floor. | (shallow + deep) ÷ 2 | Trouble Free Pool |
Free chlorine
| Rule | Formula | Basis |
|---|---|---|
| FC target from CYA Midpoint of the published target band; the calculator shows the band, not just the midpoint. | chart lookup, linear between rows | Trouble Free Pool |
| Chlorine dose Mass balance: 1 ppm is 1 mg/L. Available chlorine is the labelled percentage of the product; liquid is treated as 1.0 kg/L. | ppm × gal × 3.785 ÷ (available chlorine) | House rule |
| Dichlor adds CYA PoolMath warns that dichlor and trichlor add CYA; the 0.9 ratio follows from dichlor's composition. | ≈ 0.9 ppm CYA per 1 ppm FC | Trouble Free Pool |
Salt
| Rule | Formula | Basis |
|---|---|---|
| Salt dose 1 ppm is one pound of salt per million pounds of water; a gallon of water weighs 8.34 lb. | ppm × gal × 8.34 ÷ 1,000,000 | House rule |
| Salt target Residential cell manuals differ; most specify a band inside 2,700–3,500 ppm. 3,200 is the middle. Check your own cell's manual. | 2,700–3,500 ppm, default 3,200 | House rule |
Shock
| Rule | Formula | Basis |
|---|---|---|
| Shock level from CYA SLAM level rises with CYA; the published chart runs from 10 ppm at CYA 20 to 39 ppm at CYA 100. | chart lookup, 10 to 39 ppm | Trouble Free Pool |
Pump run time
| Rule | Formula | Basis |
|---|---|---|
| Runtime from turnovers No single US standard sets residential turnovers. 1 to 2 per day is the range in manufacturer guidance; 1.5 is the middle. | gal × turnovers ÷ (gpm × 60) | House rule |
| Slow pump, long run Affinity laws: flow falls with speed, power falls with the cube of speed. | half speed ≈ ⅛ the energy | U.S. Environmental Protection Agency — ENERGY STAR |
Heater size
| Rule | Formula | Basis |
|---|---|---|
| Heat required One BTU raises one pound of water by 1°F; a gallon weighs 8.34 lb. This is the definition of the BTU, not a manufacturer figure. | gal × 8.34 × Δ°F | House rule |
| Gas heater efficiency ENERGY STAR states the federal minimum for gas pool heaters is 82%; the default here is that minimum, so the time is not optimistic. | input × efficiency = output | U.S. Environmental Protection Agency — ENERGY STAR |
| Heat loss allowance ENERGY STAR reports covers cut heating needs by 50–70%, so an uncovered pool loses a large share of what the heater puts in. | +30% time for an uncovered pool | U.S. Environmental Protection Agency — ENERGY STAR |
Filter size
| Rule | Formula | Basis |
|---|---|---|
| Design flow Arithmetic, not a standard: average flow while the pump runs. | gal ÷ hours ÷ 60 | House rule |
| Media design rate No single national standard sets residential face velocity. These are conservative values inside the ranges manufacturers publish for each media. | cartridge 0.25, sand 15, DE 2 gpm/sq ft | House rule |
CYA / stabilizer
| Rule | Formula | Basis |
|---|---|---|
| Stabilizer dose Same mass balance as salt; stabilizer is sold as nearly pure cyanuric acid. | ppm × gal × 8.34 ÷ 1,000,000 | House rule |
| CYA dilution CYA does not evaporate or break down quickly, so water replacement is the only practical reduction. | (current − target) ÷ current | House rule |
| CYA bands Community-practice bands, not a regulation; the page says so. | 30–60 liquid, 60–90 salt | Trouble Free Pool |
Where the data comes from
Seven sources, each checked on 20 November 2026. The list is short on purpose: a source is only here if it actually states the fact the calculator uses.
- The Free Chlorine and Cyanuric Acid Relationship — Trouble Free Pool, checked Nov 20, 2026, published Jan 18, 2019
- Liquid-chlorine FC targets by CYA: 20 ppm CYA → 3–5 ppm FC; 30 → 4–6; 40 → 5–7; 50 → 6–8; 60 → 7–9; 70 → 8–10; 80 → 9–11; 90 → 10–12; 100 → 11–13.
- Minimum FC by CYA: 20 → 2; 30 → 2; 40 → 3; 50 → 4; 60 → 5; 70 → 5; 80 → 6; 90 → 7; 100 → 8 ppm.
- SLAM (shock) level by CYA: 20 → 10; 30 → 12; 40 → 16; 50 → 20; 60 → 24; 70 → 28; 80 → 31; 90 → 35; 100 → 39 ppm.
- CYA target range is 30–60 ppm for a liquid-chlorine pool and 60–90 ppm for a saltwater chlorine generator pool.
- A pool may lose 3–5 ppm of free chlorine per day in summer, and CYA may fall 5–10 ppm per month.
- These are community-maintained recommendations, not a government regulation or a manufacturer specification.
- PoolMath — pool chemistry calculator — Trouble Free Pool, checked Nov 20, 2026
- If depth varies, PoolMath uses the average of the shallow-end and deep-end depths.
- Irregular shapes are approximated by an average length and width using the rectangular formula.
- The calculator offers 10% and 12.5% liquid chlorine, 73% cal hypo and 56% dichlor among its chlorine sources.
- Solid stabilizer (CYA) can take 24 to 48 hours to dissolve.
- Dichlor and trichlor add CYA and lower pH; cal hypo adds calcium hardness.
- PoolMath advises adding less than the full calculated amount, letting it mix, and retesting.
- Pool Volume Calculator — Pentair, checked Nov 20, 2026
- Pentair's calculator works out pool water volume from the pool shape, its dimensions and its depth.
- The tool is published for homeowners as part of Pentair's pool and spa calculator collection.
- Pool & Spa Calculators — Pentair, checked Nov 20, 2026
- Pentair publishes a collection of pool and spa calculators for homeowners and professionals.
- The collection includes volume and other pool-math tools rather than a single all-purpose calculator.
- NIST Guide to the SI, Special Publication 811, Appendix B: Conversion Factors — National Institute of Standards and Technology, checked Nov 20, 2026
- 1 US gallon = 3.785 412 L.
- 1 foot = 0.3048 m exactly.
- 1 cubic foot = 28.316 85 L.
- Appendix B lists conversion factors for units outside the SI, including the US gallon and the foot.
- Swimming and Your Health — Healthy Swimming — Centers for Disease Control and Prevention, checked Nov 20, 2026
- Recreational water can spread illness or cause injury, so prevention matters.
- Common swimming-related illnesses include diarrhea, skin rashes, swimmer's ear, and eye or respiratory irritation.
- CDC publishes separate guidance for keeping a home pool safe and healthy, and for responding to contamination.
- The page was reviewed by CDC subject-matter experts in November 2026.
- Pool Pumps — U.S. Environmental Protection Agency — ENERGY STAR, checked Nov 20, 2026
- A pool pump can be the second largest energy user in a home.
- Reducing pump speed by one-half lets the pump use about one-eighth as much energy.
- Running the filter 6 hours a day instead of 24 reduces energy use by 75%.
- The federal efficiency standard for gas-fired pool heaters is 82%, and the most efficient models reach 95%.
- A pool cover can reduce heating needs by 50% to 70% and chemical use by 35% to 60%.
What this site does not do
- No prices. Pool chemicals and equipment are priced locally, and a national figure would be invented. Pages show quantities and let you price them where you shop.
- No test results. The calculators start from a reading you supply. They cannot measure free chlorine, pH, alkalinity, calcium or CYA.
- No local rules. Draining, backwash discharge, gas appliance installation and public-pool turnover are set by state and local code. The calculators estimate quantities, not compliance.
- No health advice. The chlorine numbers are a dosing plan, not a statement that water is safe to swim in. CDC publishes the health guidance; follow it.
- No prediction of algae. A correct FC does not guarantee clear water; filtration, circulation and bather load still matter.
Editorial rules
- A number appears with a source and a date, or it is marked as a house rule. There is no third category.
- Ranges stay ranges. A page that only says "6 ppm" is less useful than one that says 5 to 7 and explains why.
- When a source changes, the rule changes and the date beside the source changes with it.
- The calculators run in your browser. Nothing you type is sent anywhere, so there is no data set to leak.
- Advertising never changes a recommendation. There are no affiliate links on this site.
Found an error?
If a figure here disagrees with your product label, your test kit or your pool professional, that is worth knowing. A correction goes into the rules file with a source and a date, and every calculator that uses the rule changes with it. The label on the chemical in your hand and the reading from your own kit take priority over anything on this page.
Frequently asked
Is PoolCalc a test kit?
No. It turns a reading you already have into a quantity. It cannot tell you free chlorine, pH, CYA or calcium; only a test can. If the reading is wrong, the dose is wrong.
Where do the chlorine targets come from?
The FC/CYA target bands and shock levels are the published Trouble Free Pool chart, which is community-maintained practice rather than a regulation. The page says so wherever the chart is used.
Why are some rules marked “house rule”?
Because no one publishes a defensible figure for them — a kidney-pool multiplier, a filter face velocity, a salt target inside a manufacturer band. A house rule is our arithmetic with the reason written next to it, not a hidden assumption.
How current are the sources?
Every source carries the date we read it. The current set was checked on 20 November 2026. When a source changes, the rule that depends on it is rechecked and the date moves.